Cor Vasa 2003, 44(10):501-506

The advantages and drawbacks of stentless aortic valve bioprostheses in cardiac surgery. Initial experience with the Carpentier Edwards Prima plus prosthesis

Aleš Mokráček*, Marek Šetina
Kardiochirurgické oddělení, Nemocnice České Budějovice, České Budějovice, Česká republika

Stentless aortic bioprostheses are a recent alternative to aortic valve replacement. The paper evaluates our experience to date with stentless prostheses, their advantages and drawbacks compared with other techniques of replacement; and presents our initial data. Based on these data, stentless bioprostheses seem to provide an excellent solution to aortic valve replacement. Definitive assessment will require continuous and long-term follow-up.

Keywords: Aortic valve; Stentless bioprosthesis

Published: October 1, 2003  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Mokráček A, Šetina M. The advantages and drawbacks of stentless aortic valve bioprostheses in cardiac surgery. Initial experience with the Carpentier Edwards Prima plus prosthesis. Cor Vasa. 2003;44(10):501-506.